Telemetry Debug Demo

A schema-first timeline that correlates workload markers, PMBus rail telemetry, BMC logs, PCIe link state, thermal signals, and validation closure across multiple failure cases.

Portfolio-grade demo

All events, measurements, and failure IDs are synthetic and public-safe. They illustrate a correlation and closure model; they are not employer logs, customer data, or proof of a production AI-server deployment.

28events parsed
3failure cases
3closed cases
0schema validation errors

Case Summary

Multiple platform failures, one correlation model.

Each case has a symptom, a shared correlation ID, evidence domains, and explicit validation closure.

closed

GPU load-step rail droop causes PCIe downtrain

GPU0 core rail droop exceeds validation threshold during load step.

Closure: Regression passes cold boot, warm reboot, load-step, and thermal soak coverage.

F-2026-001 12 events BMC, PCIe, Power, Validation, Workload

closed

Retimer reset race causes Gen5 training retries

PCIe link retries during Gen5 training on warm reboot.

Closure: Warm reboot regression closes with stable Gen5 training over repeated cycles.

F-2026-002 8 events BMC, PCIe, Validation, Workload

closed

Thermal sensor mismatch masks accelerator hotspot

Local VRM hotspot estimate exceeds derating threshold while inlet remains normal.

Closure: Thermal soak passes with updated sensor map, inspection step, and derating policy.

F-2026-003 8 events BMC, Thermal, Validation, Workload

Timeline

Power, BMC, PCIe, thermal, and validation evidence aligned by timestamp.

ts_ms case domain source correlation message
0 case_power_pcie Workload host - System enters validation boot sequence.
1180 case_power_pcie Power pmbus - GPU0 core rail is stable before workload step.
1800 case_power_pcie Workload host - GPU stress workload transitions from idle to high-current phase.
1806 case_power_pcie Power pmbus F-2026-001 GPU0 core rail droop exceeds validation threshold during load step.
1812 case_power_pcie BMC bmc F-2026-001 BMC records PMBus undervoltage warning on GPU0_CORE.
1826 case_power_pcie PCIe host F-2026-001 PCIe link enters training retry window after rail droop.
1872 case_power_pcie PCIe host F-2026-001 Link downtrains after repeated training retries.
1930 case_power_pcie Validation lab F-2026-001 Scope capture confirms rail droop overlaps PCIe training retry window.
2200 case_power_pcie Validation lab F-2026-001 Mitigation selected: add bulk capacitance, tune compensation, extend OCP blanking, and guard retimer reset release.
2920 case_power_pcie Power pmbus F-2026-001 Retest rail droop stays within target after mitigation.
2965 case_power_pcie PCIe host F-2026-001 PCIe link trains at expected speed and width after mitigation.
3100 case_power_pcie Validation lab F-2026-001 Regression passes cold boot, warm reboot, load-step, and thermal soak coverage.
4000 case_retimer_refclk Workload host - Warm reboot validation begins for fabric stability check.
4060 case_retimer_refclk BMC bmc F-2026-002 BMC releases retimer reset shortly after reference clock lock indication.
4074 case_retimer_refclk PCIe host F-2026-002 PCIe link retries during Gen5 training on warm reboot.
4108 case_retimer_refclk PCIe host F-2026-002 Link falls back to Gen4 after retry budget is exhausted.
4140 case_retimer_refclk Validation lab F-2026-002 Capture shows retimer reset release is too close to refclk lock settle time.
4300 case_retimer_refclk Validation lab F-2026-002 Mitigation selected: add 25 ms guard time after refclk lock before retimer reset release.
4620 case_retimer_refclk PCIe host F-2026-002 PCIe link trains at Gen5 x16 after reset guard change.
4700 case_retimer_refclk Validation lab F-2026-002 Warm reboot regression closes with stable Gen5 training over repeated cycles.
6000 case_thermal_sensor Workload host - Thermal soak reaches steady workload phase.
6120 case_thermal_sensor Thermal bmc - Inlet temperature appears normal during thermal soak.
6130 case_thermal_sensor Thermal bmc F-2026-003 Local VRM hotspot estimate exceeds derating threshold while inlet remains normal.
6134 case_thermal_sensor BMC bmc F-2026-003 BMC derates GPU2 due to local hotspot policy.
6150 case_thermal_sensor Validation lab F-2026-003 Review finds inlet sensor cannot explain VRM hotspot; local sensor placement and cold-plate contact require inspection.
6420 case_thermal_sensor Validation lab F-2026-003 TIM contact adjusted and VRM zone threshold added to service checklist.
6900 case_thermal_sensor Thermal bmc F-2026-003 Retest hotspot temperature remains below derating threshold.
7000 case_thermal_sensor Validation lab F-2026-003 Thermal soak passes with updated sensor map, inspection step, and derating policy.

Download

Validation report

Markdown report with case summaries and full timeline.

Machine-readable

Parsed JSON report

Structured report for future visualization, filters, or role-specific summaries.