Executable proof artifact
Telemetry Debug Demo
A schema-first timeline that correlates workload markers, PMBus rail telemetry, BMC logs, PCIe link state, thermal signals, and validation closure across multiple failure cases.
All events, measurements, and failure IDs are synthetic and public-safe. They illustrate a correlation and closure model; they are not employer logs, customer data, or proof of a production AI-server deployment.
Case Summary
Multiple platform failures, one correlation model.
Each case has a symptom, a shared correlation ID, evidence domains, and explicit validation closure.
closed
GPU load-step rail droop causes PCIe downtrain
GPU0 core rail droop exceeds validation threshold during load step.
Closure: Regression passes cold boot, warm reboot, load-step, and thermal soak coverage.
closed
Retimer reset race causes Gen5 training retries
PCIe link retries during Gen5 training on warm reboot.
Closure: Warm reboot regression closes with stable Gen5 training over repeated cycles.
closed
Thermal sensor mismatch masks accelerator hotspot
Local VRM hotspot estimate exceeds derating threshold while inlet remains normal.
Closure: Thermal soak passes with updated sensor map, inspection step, and derating policy.
Timeline
Power, BMC, PCIe, thermal, and validation evidence aligned by timestamp.
| ts_ms | case | domain | source | correlation | message |
|---|---|---|---|---|---|
| 0 | case_power_pcie | Workload | host | - | System enters validation boot sequence. |
| 1180 | case_power_pcie | Power | pmbus | - | GPU0 core rail is stable before workload step. |
| 1800 | case_power_pcie | Workload | host | - | GPU stress workload transitions from idle to high-current phase. |
| 1806 | case_power_pcie | Power | pmbus | F-2026-001 | GPU0 core rail droop exceeds validation threshold during load step. |
| 1812 | case_power_pcie | BMC | bmc | F-2026-001 | BMC records PMBus undervoltage warning on GPU0_CORE. |
| 1826 | case_power_pcie | PCIe | host | F-2026-001 | PCIe link enters training retry window after rail droop. |
| 1872 | case_power_pcie | PCIe | host | F-2026-001 | Link downtrains after repeated training retries. |
| 1930 | case_power_pcie | Validation | lab | F-2026-001 | Scope capture confirms rail droop overlaps PCIe training retry window. |
| 2200 | case_power_pcie | Validation | lab | F-2026-001 | Mitigation selected: add bulk capacitance, tune compensation, extend OCP blanking, and guard retimer reset release. |
| 2920 | case_power_pcie | Power | pmbus | F-2026-001 | Retest rail droop stays within target after mitigation. |
| 2965 | case_power_pcie | PCIe | host | F-2026-001 | PCIe link trains at expected speed and width after mitigation. |
| 3100 | case_power_pcie | Validation | lab | F-2026-001 | Regression passes cold boot, warm reboot, load-step, and thermal soak coverage. |
| 4000 | case_retimer_refclk | Workload | host | - | Warm reboot validation begins for fabric stability check. |
| 4060 | case_retimer_refclk | BMC | bmc | F-2026-002 | BMC releases retimer reset shortly after reference clock lock indication. |
| 4074 | case_retimer_refclk | PCIe | host | F-2026-002 | PCIe link retries during Gen5 training on warm reboot. |
| 4108 | case_retimer_refclk | PCIe | host | F-2026-002 | Link falls back to Gen4 after retry budget is exhausted. |
| 4140 | case_retimer_refclk | Validation | lab | F-2026-002 | Capture shows retimer reset release is too close to refclk lock settle time. |
| 4300 | case_retimer_refclk | Validation | lab | F-2026-002 | Mitigation selected: add 25 ms guard time after refclk lock before retimer reset release. |
| 4620 | case_retimer_refclk | PCIe | host | F-2026-002 | PCIe link trains at Gen5 x16 after reset guard change. |
| 4700 | case_retimer_refclk | Validation | lab | F-2026-002 | Warm reboot regression closes with stable Gen5 training over repeated cycles. |
| 6000 | case_thermal_sensor | Workload | host | - | Thermal soak reaches steady workload phase. |
| 6120 | case_thermal_sensor | Thermal | bmc | - | Inlet temperature appears normal during thermal soak. |
| 6130 | case_thermal_sensor | Thermal | bmc | F-2026-003 | Local VRM hotspot estimate exceeds derating threshold while inlet remains normal. |
| 6134 | case_thermal_sensor | BMC | bmc | F-2026-003 | BMC derates GPU2 due to local hotspot policy. |
| 6150 | case_thermal_sensor | Validation | lab | F-2026-003 | Review finds inlet sensor cannot explain VRM hotspot; local sensor placement and cold-plate contact require inspection. |
| 6420 | case_thermal_sensor | Validation | lab | F-2026-003 | TIM contact adjusted and VRM zone threshold added to service checklist. |
| 6900 | case_thermal_sensor | Thermal | bmc | F-2026-003 | Retest hotspot temperature remains below derating threshold. |
| 7000 | case_thermal_sensor | Validation | lab | F-2026-003 | Thermal soak passes with updated sensor map, inspection step, and derating policy. |